Vortex Technologies Inc.

Home
Company Information
Control Loop Products
Total Facility Surge Protection
Phase Monitors-Motor and Pump Protection
120/220 V.A.C. Products
Theon 120 V.A.C.
SCM Series NEW!
(Signal Conditioning Module)
Telecommunications Products
Ground Transient Terminator
Quick Reference
Contact Information
Local Representatives
> International Reps
Request Literature
Request Quote
Links of Interest

"The Next Generation in Surge Protection!"

 

120/240/480 V.A.C. Service Entrance and Sub Panel Primary Surge Suppression Products

  Vortex Technologies Surge Pure 120/240/480 V.A.C. line of total facility surge suppression products have been designed to provide primary protection against damaging surges before they enter your facility. No other surge suppression product offers this unparalleled level of protection. From the Mach 1 and 3 Series, that is designed to protect sub panels and individual pieces of equipment, to the Mach 2, 4, 5 and 6 Series that is ideal for service entrance protection. A wide selection of power configurations as well as protection levels allow the user to select the configuration and protection level that best suits the application.  All of the Surge Pure products utilize non-degrading TVSS technology and offer a lifetime replacement warranty for Mach 2 and higher products. Mach 1 products are replacement warranted for 10 years. The Surge Pure line offers protection levels from 120,000 to 1,000,000 amps. Prevent equipment damage before it gets into your facility with the Surge Pure line of surge suppression products by Vortex Technologies, Inc.

Mach 1 Series- Protection level to 240 kamps.

Model #

M1-1120-3

M1-1208-4

M1-1240-3

M1-1240-4

M1-1480-3

M1-1480-4

Electrical System Type

1Æ

3Æ WYE

3Æ Delta

3Æ Hi-leg

3Æ Delta

3Æ WYE

Nominal A.C. Line Voltage 120/24 0 120/120/208 240/240 120/208/240 480/480 277/277/480
Frequency (Hz) 50/60  50/60 50/60 50/60 50/60 50/60
Paralleled Multi-Element “ME” Protection Modes L-N; L-L L-N; L-L & N-G L-L L-N; L-L & N-G L-L L-N; L-L & N-G
Knock Out Size for Mounting 0.5” 0.5” 0.5” 0.5” 0.5 0.5”
Leads: #12 AWG for 20 amp breaker 3+ Gnd. 4+ Gnd. 3+Gnd. 4+ Gnd. Hi-Leg 3+ Gnd. 3 or 4+ Gnd

Mach 2 Series- Protection level to 335 kamps.

Model #

M2-1120-3

M2-1208-4

M2-1240-3

M2-1240-4

M2-1480-3

M2-1480-4

Electrical System Type

1Æ

3Æ WYE

3Æ Delta

3Æ Hi-leg

3Æ Delta

3Æ WYE

Nominal A.C. Line Voltage (L-N &L-L) 120/240 120/120/208 240/240 120/208/240 480/480 277/277/480
Frequency (Hz) 50/60  50/60 50/60 50/60 50/60 50/60
Paralleled Multi-Element “ME” Protection Modes L-N; L-L L-N; L-L & N-G L-L L-N; L-L & N-G L-L L-N; L-L & N-G
Knock Out Size for Mounting 0.75” 0.75” 0.75” 0.75” 0.75 0.75”
Leads: #12 AWG for 20 amp breaker 3+ Gnd. 4+ Gnd. 3+Gnd. 4+ Gnd. Hi-Leg 3+ Gnd. 3 or 4+ Gnd

Mach 3 Series-Protection level to 335 kamps.  
 

Model #

M3-1120-3

M3-1208-4

M3-1240-3

M3-1240-4

M3-1480-3

M3-1480-4

Electrical System Type  1Æ 3Æ WYE 3Æ Delta 3Æ Hi-leg 3Æ Delta

3Æ WYE

Nominal A.C. Line Voltage (L-N &L-L) 120/240 120/120/208 240/240 120/208/240

480/480

277/277/480
Frequency (Hz)

50/60 

50/60 50/60 50/60

50/60

50/60
Single Ele3ment “SE” Protection Modes L-N; L-L L-N; L-L & N-G L-L L-N; L-L & N-G L-L L-N; L-L & N-G
AST Voltage Limiting Performance @ 2KV/180o <80 V <80 V <80 V

<80 V

<80 V <80 V

Leads: #10 AWG for 20 amp breaker

3+ Gnd.

4+ Gnd.

3+Gnd.

4+ Gnd. Hi-Leg

3+ Gnd.

3 or 4+ Gnd

Mach 4 Series-Protection level to 560 kamps.  

Model #

M4-1120-3

M4-1208-4

M4-1240-3

M4-1240-4

M4-1480-3

M4-1480-4

Electrical System Type

1Æ 3Æ WYE

3Æ Delta

3Æ Hi-leg 3Æ Delta 3Æ WYE
Nominal A.C. Line Voltage (L-N &L-L) 120/240 120/120/208 240/240 120/208/240 480/480 277/277/480
Frequency (Hz)

50/60 

50/60 50/60 50/60 50/60 50/60
Single Ele3ment “SE” Protection Modes L-N; L-L L-N; L-L & N-G L-L L-N; L-L & N-G L-L L-N; L-L & N-G
AST Voltage Limiting Performance @ 2KV/180o <80 V <80 V <80 V <80 V <80 V <80 V

Leads: #10 AWG for 20 amp breaker

3+ Gnd.

4+ Gnd.

3+Gnd.

4+ Gnd. Hi-Leg

3+ Gnd.

3 or 4+ Gnd

Mach 5 Series-Protection level to 1,000 kamps.  

Model #

M5-1120-3

M5-1208-4

M5-1240-3

M5-1240-4

M5-1480-3

M5-1480-4

Electrical System Type

1Æ 3Æ WYE 3Æ Delta 3Æ WYE or Delta

3Æ Delta

3Æ WYE

Nominal A.C. Line Voltage (L-N &L-L) 130/250 130/130/210 250/250 130/210/250 510/510 300/300/510
Frequency (Hz) 50/60  50/60 50/60 50/60 50/60 50/60
Paralleled Multi-Element “ME” Protection Modes L-N; L-L L-N; L-L & N-G L-L L-N; L-L & N-G L-L L-N; L-L & N-G
Knock Out Size for Mounting 0.75” 0.75”

0.75”

0.754” 0.75 0.75”
Leads: #12 AWG for 20 amp breaker

3+ Gnd.

4+ Gnd.

3+Gnd.

4+ Gnd. Hi-Leg

3+ Gnd.

3 or 4+ Gnd

Mach 6 Series-Protection level to 1,400 kamps.  

Model #

M6-1120-3

M6-1208-4

M6-1240-3